E4 VALUE + 6000

Regular Price €3,948.00 Special Price €3,158.40
  • Fast and tracked delivery
  • Secure payment
  • Fast and tracked delivery
  • Secure payment
Power cable: No
USB cable: Yes
RJ cable: No
RS232 cable: Yes
Câble de batterie: No
Parallel cable: No
Base for tower position: No
Multilingual Manual: Yes
Number of cables: 3
Description (2000 carac): Equipped with microprocessor-controlled On Line Double Conversion technology, E4 Value UPSs deliver perfect sine wave output current for critical low budget applications. Microprocessor-controlled On Line Double Conversion technology delivers perfect sine wave current in output and provides connected equipment with effective protection against power surges. Equipped with intelligent features (microprocessor control, Eco operating mode or even cold start), the E4 VALUE range offers RS 232 communication ports to communicate with the various protected devices. The front panel LED displays allow immediate visualization of the UPS status from the front panel (on/off, operating mode configuration, etc.).
Trade name (external documents): E4-WERT + 6000
Series description (240 carac): Equipped with On Line Double Conversion technology, E4 Value UPSs deliver perfect sine wave output current for critical low budget applications.
Product Description 1 H3 Title: The most reliable technologies
Product Description 2 H3 Title: Features adapted to all situations
Product Description 3 H3 Title: Smart features
Product Description 4 H3 Title: Manual bypass maintenance (6/10 kVA models)
Product Description 5 H3 Title: Designed for simple use
Product Desc 6 H3 Title: Communication
Product Description 1 (350 carac): On Line Double Conversion technology delivers perfect sine wave output current and provides connected equipment with effective protection against power grid surges.
Product Description 2 (350 carac): Equipped with intelligent features (microprocessor control, Eco operating mode or even cold start), the E4 VALUE range offers RS 232 and/or USB communication ports to communicate with the various protected devices. The front LED or LCD displays (depending on the model) allow immediate viewing of the UPS status from the front panel (on & off, configuration of the operating mode, etc.).
Product Description 3 (350 carac): - High power factor output (0.9 for E4 VALUE + 6000 and 10 kVA models)<br>- ECO operating mode: reduces energy consumption and costs. Allows an instant return to On Line Double Conversion when necessary<br>- Backup time: up to 30 minutes for the protection of a server and 2 computers e.g. (depending on the power of the connected devices)<br>- Cold start function
Product Description 4 (350 carac): - Included as standard with the static bypass for the E4 VALUE + 6000 and 10 kVA models<br>- Continuous power supply to connected equipment during maintenance work on the UPS via a rotary switch<br>- Guaranteed staff safety without power interruption
Product Description 5 (350 carac): An intuitive display allows immediate visualization of the status of the UPS (on/off) and simple configuration of the operating mode, etc. :<br>- LED display for 1000 to 3000 VA models<br>- LCD display for 4000 VA to 10k VA models
Product Description 6 (350 carac): The RS 232 and/or USB communication ports allow the E4 Value to communicate with the various computers and computer servers they protect:<br>- RS232 port for 1000 to 3000VA models<br>- USB and RS 232 ports for 4000VA to 10 kVA models
Warranty (year): 2
SKU - 5 digit: 67656
Product condition: New
Product Technical Version: 1
Brand: INFOSEC UPS SYSTEM
Product length (mm): 396.000000
Product height (mm): 688.000000
Product width (mm): 190.000000
Packed gross weight (kg): 67.000000
Integrated cable: No
External battery connector: Yes
Outlets type: Terminal block
EPO slot: No
UPS technology: On Line Double Conversion
Power (VA): 6000
Power (W): 5400
Phases: Single-phase/Single-phase
Format: Exclusively tower
Safety shutter: No
Number of primary phases: 1
Type of connection: Terminal block
Nominal Voltage (VAC): 208/220/230/240 VAC
Dual Input: No
Connection type: Terminal block
Voltage output type: AC
Wave form: Pure sine wave
Transfer time mains mode to battery mode (ms): 0 ms
Indicator: LCD
Automatic Voltage Regulation (AVR): No
Non-flammable plastic case: No
Battery mode efficiency: 0,9
AC mode efficiency: 92
Hot-swappable: No
Number: 16
Type : voltage (V): 12
Type : amperage-hour (ah): 9
Cold Start feature: No
Charging voltage: 218.4 VDC ±1%
Recharging time (minutes): 9 hours at 90% capacity
Maximum humidity (%): 90
Minimum humidity (%): 20
Humidity range: 20-90 % RH @ 0- 40°C (without condensation)
Noise level: Less than 55dBA at 1 meter
Type: Indoor
Standard static bypass (included): Yes
Manual bypass: Included internally
Parallelable: No
Parallel Kit: Not available
Varistor surge protection: No
Audible alarms: Low battery, Overload, Default
Visual Indicators: Charge level, Battery level, AC mode, Battery mode, Bypass mode, Default
Communication via software available: Yes
Compatible communication software: InfoPower
SNMP: Yes
CE: Yes
RoHS: Yes
Ul: No
Power (W): 5400
Item Returns: This item can be returned

Characteristics

UPS technology

On Line Double Conversion

Outlets type

Terminal block

Warranty (year)

2

Format

Exclusively tower

Indicator

LCD

Presentation

The most reliable technologies

On Line Double Conversion technology delivers perfect sine wave output current and provides connected equipment with effective protection against power grid surges.

Features adapted to all situations

Equipped with intelligent features (microprocessor control, Eco operating mode or even cold start), the E4 VALUE range offers RS 232 and/or USB communication ports to communicate with the various protected devices. The front LED or LCD displays (depending on the model) allow immediate viewing of the UPS status from the front panel (on & off, configuration of the operating mode, etc.).

Smart features

- High power factor output (0.9 for E4 VALUE + 6000 and 10 kVA models)
- ECO operating mode: reduces energy consumption and costs. Allows an instant return to On Line Double Conversion when necessary
- Backup time: up to 30 minutes for the protection of a server and 2 computers e.g. (depending on the power of the connected devices)
- Cold start function

Manual bypass maintenance (6/10 kVA models)

- Included as standard with the static bypass for the E4 VALUE + 6000 and 10 kVA models
- Continuous power supply to connected equipment during maintenance work on the UPS via a rotary switch
- Guaranteed staff safety without power interruption

Designed for simple use

An intuitive display allows immediate visualization of the status of the UPS (on/off) and simple configuration of the operating mode, etc. :
- LED display for 1000 to 3000 VA models
- LCD display for 4000 VA to 10k VA models

Communication

The RS 232 and/or USB communication ports allow the E4 Value to communicate with the various computers and computer servers they protect:
- RS232 port for 1000 to 3000VA models
- USB and RS 232 ports for 4000VA to 10 kVA models

Technical specifications

General specifications

UPS technology: On Line Double Conversion
Power (VA): 6000
Power (W): 5400
Phases: Single-phase/Single-phase
Format: Exclusively tower

Physical characteristics

Product length (mm): 396
Product height (mm): 688
Product width (mm): 190
Packed gross weight (kg): 67

Input technical characteristics

Number of primary phases: 1
Type of connection: Terminal block
Nominal Voltage (VAC): 208/220/230/240 VAC

Output technical characteristics

Connection type: Terminal block
Voltage output type: AC
Wave form: Pure sine wave
Transfer time mains mode to battery mode (ms): 0 ms

Output connection

External battery connector: Yes
Outlets type: Terminal block

Efficiency

Battery mode efficiency: 0,9
AC mode efficiency: 92

Battery

Number: 16
Type : voltage (V): 12
Type : amperage-hour (ah): 9
Charging voltage: 218.4 VDC ±1%
Recharging time (minutes): 9 hours at 90% capacity
Material: sealed lead

Display

Indicator: LCD

Indicators & alarms

Audible alarms: Low battery, Overload, Default
Visual Indicators: Charge level, Battery level, AC mode, Battery mode, Bypass mode, Default

Bypass

Standard static bypass (included): Yes
Manual bypass: Included internally

Parallel connection

Parallel Kit: Not available

Management and communication

Communication via software available: Yes
Compatible communication software: InfoPower
SNMP: Yes

Environment

Maximum humidity (%): 90
Minimum humidity (%): 20
Humidity range: 20-90 % RH @ 0- 40°C (without condensation)
Noise level: Less than 55dBA at 1 meter
Type: Indoor

Norms

CE: Yes
RoHS: Yes

File Downloads

Documentation
pdf
(Size: 2.6 MB)
Guide d'utilisation
pdf
(Size: 3.1 MB)

Contenu du packaging

USB cable: Yes
RS232 cable: Yes
Multilingual Manual: Yes
Number of cables: 3
Write Your Own Review
You're reviewing:E4 VALUE + 6000
Expertise_Copy

30 years of expertise

Livraison

Fast and tracked delivery

paiement

Secure payment

Assistance

Personalized support

Planet

Environmental commitment